Construction Guides

Acoustic Treatment Layouts

Room-by-room treatment plans with plan views and reflected ceiling plans

4
Treated Rooms
--
Total Area (m²)
--
Best RT60 (s)
BUILDER CUSTOMIZATION GUIDE -- TREATMENT LAYOUTS

CUSTOMIZABLE -- Fabric wrap colour, texture, and pattern on absorption panels, ceiling cloud suspension rod brand, mounting bracket finish colour, panel frame edge profile colour, decorative diffuser surface finish (stain or paint).

DO NOT ALTER -- Panel core material and density, panel thickness, NRC rating per position, placement coordinates on walls and ceiling, coverage area per room, ceiling cloud dimensions and hang height, bass trap corner placement and depth, diffuser well depth sequence, air gap behind panels. Treatment positions are calculated for specific RT60 and frequency response targets.

VO Live

Area 5.12 m² NC Target NC-20 RT60 Target 0.15 - 0.25 s RT60 Achieved 0.20 s

Walls

70% coverage with 50mm rockwool panels (fabric wrapped)

Ceiling

Full acoustic tile

Bass Traps

4x corner-mounted, floor-to-ceiling

Floor

Carpet on float floor

Adjustable Absorption — Motorized Curtain

Ceiling-mounted C-rail with DC motor (<20 dBA). 450 g/m² acoustic velour, double-layered, floor-to-ceiling (2.75m drop). Coverage: 3.2 m².

Positions:

  • “Dead” — Curtain retracted, panels exposed → RT60 ~0.20s (default recording)
  • “Live” — Curtain deployed, warmer sound → RT60 ~0.27s (narration/dialogue)

Both positions within acceptance range (0.15–0.30s). Motor operates between takes only.

Control: Wall switch + wireless remote. Optional DAW MIDI macro integration.

P Plan View (Top Down)
D3 3.22 m 1.96 m VO LIVE
Absorption Panels
Bass Traps
Door
R Reflected Ceiling Plan (RCP)
ACOUSTIC CEILING TILE (100%) DIFFUSER 3.22 m 1.96 m
Acoustic Tile
HVAC Diffuser
Light Fixture

E Wall Elevations — VO Live

North Wall — 3.22 m wide (Concrete)
FLOOR CEILING 2.75 m BASS TRAP 300mm BASS TRAP 300mm Rockwool RWA45 50mm, fabric wrapped 1200 x 600 mm 10 cm AFF panels: 10-265 cm AFF 322 cm RWA45 150mm 8 panels • Rockwool RWA45 50mm (fabric wrapped) • 25 mm air gap behind
South Wall — 2.61 m wide (Partition to Control Room)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 150mm D3 80 x 220 cm OBS. WINDOW 80 x 50 cm sill 100cm AFF RWA45 50mm Rockwool RWA45 Rockwool RWA45 RWA45 261 cm ~5 panels • Rockwool RWA45 50mm (fabric wrapped) • 25 mm air gap behind
East Wall — 1.96 m wide (Buffer Spine)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 BASS TRAP 300mm Rockwool RWA45 50mm (fabric wrapped) 1200 x 600 mm 10cm AFF 196 cm 4 panels • Rockwool RWA45 50mm (fabric wrapped) • 25 mm air gap
West Wall — 1.96 m wide (Diagonal Concrete)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 BASS TRAP 300mm Rockwool RWA45 50mm (fabric wrapped) 1200 x 600 mm 10cm AFF 196 cm 4 panels • Rockwool RWA45 50mm (fabric wrapped) • 25 mm air gap
Absorption — Rockwool RWA45 50mm, fabric wrapped, 25mm air gap behind
Bass Trap — Rockwool RWA45 150mm, corner-mounted, floor-to-ceiling (2.75m)
Observation Window (triple-pane)
Untreated Wall (gypsum face)

Treatment Schedule — VO Live

Element Treatment Type Material Coverage Thickness
Wall N Absorption Rockwool RWA45 (fabric wrapped) 70% 50 mm
Wall S Absorption Rockwool RWA45 (fabric wrapped) 70% 50 mm
Wall E (Buffer) Absorption Rockwool RWA45 (fabric wrapped) 70% 50 mm
Wall W (Diagonal) Absorption Rockwool RWA45 (fabric wrapped) 70% 50 mm
Ceiling Absorption Rockfon Sonar E (NRC 0.90) 100% 20 mm tile
Floor Carpet Carpet on float floor (Sylomer SR 28) 100% 15 mm + 36 mm deck
Corners (x4) Bass Trap Rockwool RWA45 (45 kg/m³, 150mm) 4 corners Floor-to-ceiling

Control Room

Area 4.96 m² NC Target NC-25 RT60 Target 0.30 - 0.40 s RT60 Achieved 0.30 s

Front Wall

50mm absorption behind monitors

Side Walls

Early reflection panels (first reflection points)

Rear Wall

QRD diffuser array (80x80cm panels)

Ceiling

Partial acoustic cloud (60% coverage)

Bass Traps

4x corner-mounted

Floor

Carpet on float floor

P Plan View (Top Down)
ABSORPTION 1st REF QRD DIFFUSERS L R SWEET SPOT (72%) WINDOW D2 DIAGONAL BUFFER SPINE 2.61 m (front) 2.00 m (rear) 2.15 m CONTROL
Absorption
Reflection Panels
QRD Diffusers
Bass Traps
R Reflected Ceiling Plan (RCP)
ACOUSTIC CLOUD (60%) DIFFUSER monitors below 2.61 m (front) 2.15 m
Acoustic Cloud
HVAC Diffuser
Light Fixture

E Wall Elevations — Control Room

North / Front Wall — 2.61 m wide (Monitors & Absorption)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 150mm OBS. WINDOW 80 x 50 cm sill 100cm AFF MONITORS 50mm Absorption RWA45 fabric wrap D3 80 x 220 cm to VO Live 195cm AFF (top) 261 cm 3 panels + D3 door • 50mm Rockwool RWA45 behind monitors • 25 mm air gap
South / Rear Wall — 2.00 m wide (QRD Diffusers)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 150mm BASS TRAP 300mm QRD DIFFUSER 800 x 800 mm 120mm deep QRD DIFFUSER 800 x 800 mm 50cm AFF QRD zone: 50-220cm 200 cm 2 QRD diffusers • 800 x 800 mm each • 120mm deep
East Wall — 2.15 m wide (Buffer Spine, Door D2)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 BASS TRAP 300mm D2 80 x 220 cm 1st REFLECTION RWA45 50mm 800 x 550 mm top 215cm AFF 215 cm 1st reflection panel • RWA45 50mm • 25 mm air gap
West Wall — ~2.15 m wide (Diagonal)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 BASS TRAP 300mm 1st REFLECTION RWA45 50mm, 1200x600 1st REFLECTION RWA45 50mm, 1200x600 ~215 cm center 1200mm 2 panels, 1st reflection point • 25 mm air gap
Ceiling Plan (View from Below) — 60% Acoustic Cloud
60% ACOUSTIC CLOUD Suspended panels, 200mm drop ● = suspension point ▲ N (monitors) 261 cm (front) 215 cm
Absorption Panel — Rockwool RWA45 50mm, fabric wrapped, 25mm air gap
QRD Diffuser — 800 x 800 mm panels, 120mm deep
Bass Trap — Rockwool RWA45 150mm, corner-mounted, floor-to-ceiling (2.75m)
Observation Window (triple-pane)
Untreated Wall (gypsum face)

Treatment Schedule — Control Room

Element Treatment Type Material Coverage Thickness
Wall N (Front) Absorption Rockwool RWA45 behind monitors 80% 50 mm
Wall E (Side) Absorption Rockwool RWA45 (first reflection panel) 40% 50 mm
Wall W (Side) Absorption Rockwool RWA45 (first reflection panel) 40% 50 mm
Wall S (Rear) Diffusion QRD diffuser (80x80cm panels) 80% 120 mm
Ceiling Absorption Rockfon Sonar E cloud panels (NRC 0.90) 60% 20 mm tile
Floor Carpet Carpet on float floor (Sylomer SR 28) 100% 15 mm + 36 mm deck
Corners (x4) Bass Trap Rockwool RWA45 (45 kg/m³, 150mm) 4 corners Floor-to-ceiling

Video/Podcast Studio

Area 11.80 m² NC Target NC-25 RT60 Target 0.25 - 0.40 s RT60 Achieved 0.25 s

Walls

50% absorption, 20% diffusion, 30% reflective

Ceiling

Acoustic tile (80% coverage)

Bass Traps

4x corner-mounted

Floor

Float floor (no carpet — hard surface for rolling equipment)

P Plan View (Top Down)
3.60 m CAMERA THROW D4 5.00 m 2.36 m VIDEO STUDIO
Absorption (50%)
Diffusion (20%)
Bass Traps
Door
R Reflected Ceiling Plan (RCP)
ACOUSTIC TILE (80%) REFLECTIVE STRIP (20%) DIFF 1 DIFF 2 5.00 m 2.36 m
Acoustic Tile (80%)
Reflective Strip
HVAC Diffuser
Light Fixture

E Wall Elevations — Video/Podcast Studio

North Wall — 5.00 m wide
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 150mm BASS TRAP 300mm Absorption Panel RWA45 50mm QRD Diffuser 1200x600mm ABS DIFF ABS DIFF ABS DIFF ABS bottom row: 105cm AFF top row: 255cm AFF 500 cm Alternating: RWA45 50mm absorption (blue) & QRD diffuser (purple) • 1200x600mm • 25mm air gap
South Wall — 5.00 m wide (Door D4 near West End)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 150mm BASS TRAP 300mm D4 90 x 220 cm RWA45 50mm Absorption RWA45 50mm DIFF DIFF ABS DIFF ABS 500 cm Panels around D4 • RWA45 50mm absorption & QRD diffusion • 1200x600mm • 25mm air gap
East Wall — 2.36 m wide
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 BASS TRAP 300mm Absorption RWA45 50mm, 1200x600 QRD Diffuser 1200x600mm Absorption RWA45 50mm 105cm AFF 236 cm 2 absorption (RWA45) + 1 QRD diffuser • 1200x600mm • 25mm air gap
West Wall — 2.36 m wide (Buffer Spine)
FLOOR CEILING 2.75 m BASS TRAP 300mm RWA45 BASS TRAP 300mm QRD Diffuser 1200x600mm Absorption RWA45 50mm, 1200x600 QRD Diffuser 1200x600mm 105cm AFF 236 cm 1 absorption (RWA45) + 2 QRD diffusers • 1200x600mm • 25mm air gap
Ceiling Plan (View from Below) — 80% Acoustic Tile Coverage
80% ACOUSTIC TILE Grid-suspended panels, 600 x 600 mm tiles REFLECTIVE PERIMETER STRIP (20%) ● = suspension point ▲ N 500 cm 236 cm
Absorption Panel — Rockwool RWA45 50mm, fabric wrapped, 25mm air gap
QRD Diffuser — 1200 x 600 mm panels
Bass Trap — Rockwool RWA45 150mm, corner-mounted, floor-to-ceiling (2.75m)
Untreated Wall (gypsum face — 30% reflective)

Treatment Schedule — Video/Podcast Studio

Element Treatment Type Material Coverage Thickness
Wall N Absorption Rockwool RWA45 (fabric wrapped) 50% 50 mm
Wall N (alt.) Diffusion QRD diffuser panels 20% 120 mm
Wall S Absorption Rockwool RWA45 (fabric wrapped) 50% 50 mm
Wall S (alt.) Diffusion QRD diffuser panels 20% 120 mm
Wall W (Buffer) Absorption Rockwool RWA45 (fabric wrapped) 50% 50 mm
Wall E Absorption Rockwool RWA45 (fabric wrapped) 50% 50 mm
Ceiling Absorption Rockfon Sonar E (NRC 0.90) 80% 20 mm tile
Floor Float Floor Float floor plywood (Sylomer SR 28 pads) 100% 36 mm deck + 15 mm pad
Corners (x4) Bass Trap Rockwool RWA45 (45 kg/m³, 150mm) 4 corners Floor-to-ceiling

Editing Suite

Area 8.00 m² NC Target NC-35 RT60 Target 0.00 - 0.50 s RT60 Achieved 0.36 s

Walls

30% absorption (minimal — least critical room)

Ceiling

Standard acoustic tile

Bass Traps

None needed (NC-35 tolerance)

Floor

Carpet on float floor

P Plan View (Top Down)
DESK 1 DESK 2 DESK 3 D1 D2 D4 5.00 m 1.60 m EDITING
Absorption (30%)
Workstation
Door
R Reflected Ceiling Plan (RCP)
STANDARD ACOUSTIC TILE (100%) DIFFUSER 5.00 m 1.60 m
Standard Tile
HVAC Diffuser
Light Fixture

E Wall Elevations — Editing Suite

North Wall — 5.00 m wide (Partition to Video Studio • Door D4)
ACOUSTIC CEILING — 2.75 m AFF FLOOR (FFL) D4 90 × 210 cm to Video Studio Absorption Panel Rockwool RWA45 50mm (fabric wrapped) 1200 × 600 mm Absorption Panel Rockwool RWA45 50mm (fabric wrapped) 1200 × 600 mm 500 cm (5.00 m) 275 cm (2.75 m) 260 cm to D4 90 cm 150 cm 90 cm AFF (bottom) 60 cm panel 210 cm door h. 2 panels • 1200×600 mm each • 50 mm Rockwool RWA45 • 25 mm air gap behind • no bass traps
South Wall — 5.00 m wide (Exterior Rebuilt • Door D1 SE Corner • 3 Workstations)
ACOUSTIC CEILING — 2.75 m AFF FLOOR (FFL) D1 90 × 210 cm EXTERIOR ENTRY DESK 1 DESK 2 DESK 3 Absorption Panel Rockwool RWA45 50mm (fabric wrapped) 1200 × 600 mm Absorption Panel Rockwool RWA45 50mm (fabric wrapped) 1200 × 600 mm 500 cm (5.00 m) 275 cm (2.75 m) 410 cm to D1 90 cm D1 40 120 60 120 90 cm AFF (btm) 60 cm panel 210 cm door h. 2 panels • 1200×600 mm each • 50 mm Rockwool RWA45 • 25 mm air gap • desks shown dashed • no bass traps
East Wall — 1.60 m wide (Server Wall • No Door • 1 Panel)
ACOUSTIC CEILING — 2.75 m AFF FLOOR (FFL) Absorption Panel Rockwool RWA45 50mm (fabric wrapped) 1200 × 600 mm 160 cm (1.60 m) 275 cm (2.75 m) 20 120 cm 20 90 cm AFF (btm) 60 cm panel 150 cm (top AFF) 1 panel • 1200×600 mm • 50 mm Rockwool RWA45 • 25 mm air gap • no bass traps
West Wall — 1.60 m wide (Buffer Spine • Door D2 at 70 cm from South • No Panels)
ACOUSTIC CEILING — 2.75 m AFF FLOOR (FFL) — S on left, N on right D2 80 × 210 cm to Buffer Spine 70 cm (no panel) 10 cm 160 cm (1.60 m) 275 cm (2.75 m) 70 cm to D2 80 cm D2 10 210 cm door h. 0 panels • door occupies 80/160 cm • 70 cm strip south & 10 cm strip north • no bass traps
Ceiling Plan — Armstrong Ultima+ Fine Fissured NRC 0.70 • Full Coverage • Standard 600×600 mm Grid
ARMSTRONG ULTIMA+ NRC 0.70 — FULL COVERAGE 600 × 600 mm tiles • Standard suspended T-bar grid • 19 mm thick D4 D1 D2 HVAC DIFF. LT LT LT 500 cm (5.00 m) — E-W 160 cm (1.60 m) — N-S Grid: 8 full tiles (480 cm) + 2 cut tiles (10 cm each) E-W • 2 full tiles (120 cm) + 1 cut tile (40 cm) N-S Total: Armstrong Ultima+ Fine Fissured, NRC 0.70, 19 mm • Standard 24 mm T-bar grid, 2400 mm main runners E-W
Absorption Panel — Rockwool RWA45 50mm, fabric wrapped, 25mm air gap behind
Untreated Wall (gypsum face — 70% reflective)
Door opening
Workstation desk (furniture, not acoustic treatment)

Note: Editing Suite has no bass traps (NC-35 tolerance). 30% wall absorption is minimal by design — this is the least acoustically critical room.

Treatment Schedule — Editing Suite

Element Treatment Type Material Coverage Thickness
Wall N Absorption Rockwool RWA45 (fabric wrapped) 30% 50 mm
Wall S Absorption Rockwool RWA45 (fabric wrapped) 30% 50 mm
Wall W (Buffer) Absorption Rockwool RWA45 (fabric wrapped) 30% 50 mm
Wall E Absorption Rockwool RWA45 (fabric wrapped) 30% 50 mm
Walls (Remaining) Reflective Painted gypsum (existing finish) 70% N/A
Ceiling Absorption Armstrong Ultima+ Fine Fissured (NRC 0.70) 100% 19 mm tile
Floor Carpet Carpet on float floor (Sylomer SR 28) 100% 15 mm + 36 mm deck
Corners None No bass traps required (NC-35 tolerance)

Treatment Coverage Overview

Total absorption and diffusion areas per room, derived from treatment schedules above.

VO Live
--
Absorption Area
0 m²
Diffusion Area
4 bass traps, full ceiling tile, carpet floor
Control Room
--
Absorption Area
--
Diffusion Area
4 bass traps, 60% cloud, carpet floor
Video Studio
--
Absorption Area
--
Diffusion Area
4 bass traps, 80% ceiling, float floor (no carpet)
Editing Suite
--
Absorption Area
0 m²
Diffusion Area
No bass traps, standard tile, carpet floor

Installation Requirements

Critical requirements for acoustic treatment installation. Follow these precisely to achieve target NC and RT60 values.

Critical Installation Requirements

  1. Panel Mounting Heights: Wall absorption panels should be centered at ear height (1200 mm from finished floor) for seated positions in the Control Room and Editing Suite, and at standing mic height (1450 mm) in the VO Live room. Video Studio panels alternate between the two heights for broadband coverage.
  2. First Reflection Point Calculation: In the Control Room, use the mirror trick method. Sit at the sweet spot (72% of room depth from front wall, 1.54 m) and have an assistant slide a mirror along each side wall. Where the monitor is visible in the mirror marks the first reflection point. Place absorption panels centered on these points.
  3. Bass Trap Corner Coverage: Floor-to-ceiling bass traps in VO Live, Control, and Video Studio rooms must fill the tri-corner junctions completely. Use Rockwool RWA45 (45 kg/m³, 150mm) cut in 300mm-wide triangular prisms. Seal all edges against wall faces with acoustic sealant. Fabric wrap must be acoustically transparent.
  4. Adhesive vs Mechanical Fixing: Absorption panels on gypsum walls use Z-clip mechanical fasteners (not adhesive alone). Each panel requires minimum 4 fixings. QRD diffusers in the Control Room rear wall mount on French cleats rated for 15 kg per panel. Ceiling tiles sit in a suspended T-bar grid system.
  5. Fire Rating Requirements: All acoustic materials must carry Class A fire rating (ASTM E84). Fabric wrap on panels must be inherently flame-retardant, not treated. Rockwool products are non-combustible by nature. Maintain fire-rated assembly continuity through all penetrations per local code.
  6. Air Gap Behind Panels: Wall-mounted absorption panels require a 25 mm minimum air gap between the panel back and the wall surface. This air gap significantly improves low-frequency absorption performance. Use standoff clips or spacers to maintain this gap consistently.
  7. Ceiling Cloud Suspension (Control Room): The acoustic cloud in the Control Room hangs 200 mm below the ceiling slab on threaded rods with vibration isolators. Cloud panels must not make rigid contact with walls. Maintain a 50 mm perimeter gap between cloud edges and all wall surfaces.
  8. QRD Diffuser Alignment: Rear wall QRD diffusers in the Control Room must be installed with wells oriented vertically. Panels are mounted flush edge-to-edge with no gaps. Bottom edge at 600 mm from finished floor, top edge at approximately 2200 mm. Surface must remain exposed (no paint or film).
  9. Observation Window Integration: Treatment panels adjacent to the VO Live observation window (80 x 50 cm triple-pane) must terminate with a clean edge. Use aluminium trim channels at all panel-to-window jamb interfaces. No absorption material may obstruct the window reveal.
  10. Sequencing with Other Trades: All acoustic treatment installation follows HVAC diffuser installation and electrical rough-in. Treatment panels must accommodate existing penetrations. Cut panels on-site using a sharp knife (not a saw) to prevent fiber release. Vacuum all cut edges before fabric wrapping.
SSOT Version: --
← Back to Index ↑ Back to Top