Electrical, data, and pipe penetration protocols for maintaining acoustic isolation across all STC-rated assemblies.
CUSTOMIZABLE -- Conduit and cable tray brand, junction box manufacturer, cable labelling system and colour coding, face plate style on finished side of wall.
DO NOT ALTER -- Sleeve oversizing dimensions, acoustic sealant type and application method, putty pad specifications around electrical boxes, fire-stop and smoke-seal products, boot and grommet specifications at duct penetrations, number of cables per sleeve, back-fill material and packing sequence. Every penetration is a potential STC weak point -- sealing protocols must be followed exactly as specified.
Every penetration through an STC-rated assembly must be sealed to the same STC rating as the wall. One unsealed hole destroys the entire wall's acoustic performance. A 1% opening in an STC 55 wall can reduce it to STC 35 or worse.
Two dedicated conduit penetrations carry all audio signal cabling between production rooms and the Control Room. Each conduit is sealed as a permanent penetration — not a removable sleeve.
| Stagebox | Route | Conduit | Wall Penetration | Sealing Method | Cables Inside |
|---|---|---|---|---|---|
| SB-01 | Control Room ↔ VO Live | 32 mm steel conduit | Through VO/Control partition wall (W6) | Fire-rated putty both ends + acoustic sealant packing around cable bundle inside conduit | 4× Mogami W2534 quad-core (XLR), 4× Mogami W2549 (TRS), 1× Cat6A |
| SB-02 | Control Room ↔ Video Studio (via Editing) | 32 mm steel conduit | Two penetrations: (1) Video Studio/Editing partition (W7), (2) Editing/Control junction via ceiling tray to buffer wall sealed sleeve | Fire-rated putty both ends of each penetration + acoustic sealant packing. Junction box in Editing room ceiling plenum. | 4× Mogami W2534 quad-core (XLR), 4× Mogami W2549 (TRS), 2× BNC (75Ω), 2× Cat6A |
Each duct branch serving a production room includes an inline silencer downstream of the buffer wall penetration. Refer to the HVAC silencer schedule for attenuation values and terminal velocities per run. Silencer lengths and NC targets are defined in the SSOT constants.
Green dots indicate approved penetration locations. Red zones are strictly prohibited. All cable penetrations route through the Editing room.